Product Details:
| Brand | CEM |
| Model Name / Number | DT156 |
| Type | F / NF |
| Measuring Range | 0 - 1250 um |
| Accuracy | 1 % of reading |
The DT-156 coating thickness gauge works either on the magnetic induction principle or on the eddy current principle, depending on the type of probe used. You can select the type of probe via MENU system or it will work automatically.
|
Sensor probe |
F |
N |
|
Working principal |
Magnetic induction |
Eddy current principal |
|
Measuring range |
0~1250µm |
0~1250µm |
|
0~49.21mils |
0~49.21mils |
|
|
Guaranteed tolerance (of reading) |
0~850µm |
0~850µm |
|
(±3%+1µm) |
(±3%+1.5µm) |
|
|
850µm~1250µm |
850µm~1250µm |
|
|
(±5%) |
(±5%) |
|
|
0~33.46mils |
0~33.46mils |
|
|
(±3%+0.039mils) |
(±3%+0.059mils) |
|
|
3346mils~49.21mils |
33.46mils~49.21mils |
|
|
(±5%) |
(±5%) |
|
|
Precision |
0~50µm (0.1µm) |
0~50µm (0.1µm) |
|
50µm~850µm (1µm) |
50µm~850µm (1µm) |
|
|
850µm~1250µm (0.01mm) |
850µm~1250µm (0.01mm) |
|
|
0~1.968mils (0.001mils) |
0~1.968mils (0.001mils) |
|
|
33.46mils~49.21mils (0.1mils) |
33.46mils~49.21mils (0.1mils) |
|
|
Minimum curative radius |
1.5mm |
3mm |
|
|